Environmental Monitoring Services
Chemicals Monitored
Evergreen Medical monitors for the following chemicals:
- Waste Anesthetic Gases (Nitrous Oxide & Halogenated Agents)
- Laboratory Chemicals (Formaldehyde, Toluene, Xylene, etc.)
- Glutaraldehyde
- Ethylene Oxide
- Acetic Acid
On-site Evaluations
We provide:
Employee
Exposure Monitoring—Our technicians use the highly sensitive MIRAN SapphIRe
to detect and measure work-place, airborne chemicals. Our testing includes
the applicable ceiling level, 15 minute STEL and an eight-hour TWA (as
applicable).
- Leak Testing
- Air Exchange Measurements
- Supply and Exhaust Flows
- Positive/Negative Pressure Measurements
- Work Place and Practice Evaluations
Additional Testing includes:
- Isolation Room Ventilation—CAD schematics are provided for each
isolation room.
- Anesthetic Vaporizer Accuracy, Maintenance and Calibration
- Indoor Air Quality (bacteria and fungi)
Testing results are recorded on laptops at the time of testing to provide accurate and timely reports.
- Testing is performed in accordance with JCAHO, OSHA, NIOSH, DHHS and other regulatory agency requirements
and recommendations.
Click on images below
for samples:

Passive Dosimeter Badge Monitoring
We provide badges for over 200 different chemicals, including Formaldehyde,
EtO, and Nitrous Oxide. Badges are provided and analyzed by an AIHA accredited laboratory, and can
measure a 15 minute STEL or an eight-hour TWA. They have a shelf-life of 6-12
months. When needed, results can be faxed or emailed within 48 hours.
|
|
|
|